Send Email To Us
Email:[email protected]
  • BHO extractor closed loop

    BHO extractor closed loop

    Sells 1 lb, 10 lb, 20 lb, 50 lb and other closed-loop extractors, which are made of stainless steel, are inexpensive and have high extraction efficiency.

  • SPD2L short path distillation

    SPD2L short path distillation

    Sells a complete set of SPD-2L mini short-path distillation equipment, which is widely used in pharmaceutical, laboratory fractionation and purification, food and beverage, essential oil and other industries.

  • RE5299 rotary evaporator

    RE5299 rotary evaporator

    Our company's rotary evaporator RE-5299 rotary evaporator uses high borosilicate glass, with sufficient storage, cheap and good quality.

  • RE201D 301 501 rotary evaporator

    RE201D 301 501 rotary evaporator

    RE-201D RE-301 RE-501 rotary evaporator is a small rotary evaporator (mini rotary evaporator), beautiful appearance, small and light, top-rotating sealed, good vacuum.

  • S80L 100L glass jacketed reactor

    S80L 100L glass jacketed reactor

    Is specializes in manufacturing and selling laboratory large-capacity glass reactors. Double-layer glass reactors can be customized and processed according to customer needs. The design is unique, safe and convenient.

  • S10L 20L 30L 50L glass jacketed reactor

    S10L 20L 30L 50L glass jacketed reactor

    Is specializes in manufacturing and selling S-10L S-20L S-30L S-50L laboratory glass reactors, which can perform various solvent synthesis reactions under constant temperature conditions.

  • FD03H freeze dryer

    FD03H freeze dryer

    Home lab freeze dryer is a mini vacuum freeze dryer. We are a freeze dryer manufacturer in China. We sell freeze dryers, which are very suitable for home use.

  • DZF6500 vacuum drying oven

    DZF6500 vacuum drying oven

    The vacuum drying oven with vacuum pump can achieve the effect of vacuum drying.Provides vacuum drying ovens of various specifications.

  • KDM100 molecular distillation

    KDM100 molecular distillation

    A professional laboratory molecular distillation system manufacturer in China. Its evaporation efficiency is very high, it can reduce the retention time and has the smallest time delay.

Categories
Related Posts

chiller running but not cooling

Chiller Phase Reversal – Poor Cooling and Pumping

Jan 30, 2006· Scroll compressor running but is loud with poor cooling and pumping performance. At startup: This condition commonly occurs at startup. When the chiller is run tested at the factory, there is a 50% chance that your building power will be orientated the same as the factory. If your building is out of phase with the chillers factory orientation

Why is the chiller not cooling?

May 14, 2020· The dry filter is clogged The clogging of the drying filter will affect the heat exchange effect of the condenser, and the cooling effect of the whole machine is not good. Therefore, it is necessary to regularly check and clean the filter. If the clogging is serious, it is recommended to replace the new drying filter.

Refrigerator - Not Cooling Enough - GE Appliances

Refrigerator - Not Cooling Enough. If the refrigerator is running but not cooling at all or is not cold enough, several factors may influence the temperature. Check the following: Check the temperature control settings: For Dial or Digital Readout Models, adjust your temperature control by one nuer higher for a cooler temperature setting.

Troubleshooting Common Chiller Problems - Process Cooling

Jul 01, 2008· Common Chiller Problems and Possible Causes 1. CHILLER DOES NOT POWER UP Improper line voltage or loose connection Incorrect phase connection (three-phase units) Blown circuit breaker or fuse Power switch in "off" position 2. NO PUMPING OR INSUFFICIENT FLUID FLOW Improper or fluctuating line voltage Insufficient fluid in reservoir

How Cooling Tower vs Chillers Work

Dec 03, 2021· A chiller is used to cool the water in the building, while a cooling tower is typically found outside. A chiller needs more energy than a cooling tower does because it needs to heat the water before it cools it, so they are often used in buildings with high efficiency. The efficiency of chillers can be measured in tons of refrigeration (TR

Technotrans chiller not chilling | Color Printing Forum

Jun 21, 2012· On our DI 46 Plus the TechnoTrans Chiller is pumping water (pressure 4.5 bar when running) However it is warming up over 30 degrees Centigrade though set at 23 and when it warms up the printing tones in. I see the cooling fan on the chiller is not running and the compressor feels cool to the touch so I suspect it is not operating.

GLYCOL CHILLER SYSTEM TROUBLESHOOTING By Jim VanderGiessen

Sep 30, 2015· To start, check the rotation of the glycol pump. If a centrifugal pump’s rotation is reversed it will still pump glycol, but only a fraction of the design flow. The reduced flow will cause

Chiller doesn''t like to run when cold - Any advice

Feb 19, 2015· Basically, if the compressor is working, it will continue to operate to lower temperatures, but once the glycol gets to the set temp and it shuts off, it won''t come back on. The local tech indied that "it wasn''t designed for this temp" and he said that if we insulate it, it may help keep the internal temps warmer and help it continue to run

SOLVED: Why is my cold water not cold? - GE Profile Tri

Apr 24, 2014· If the unit is getting power then the compressor is not working correctly. It could be out of Freon or the compressor its self is shot. Which is why you aren''t getting cold water. If you are getting cold water not hot then the heater unit is burnt. In some units the waste heat from the compressor is used which can explain why you''re not getting

The Ultimate Guide to Chiller Systems. Everything You Need

Nov 16, 2017· Chillers provide a continuous flow of coolant to the cold side of a process water system at a desired temperature of about 50°F (10°C). The coolant is then pumped through the process, extracting heat out of one area of a facility (e.g., machinery, process equipment, etc.) as it flows back to the return side of the process water system.

A guide on using aquarium chillers to cool tanks

Dec 12, 2021· Pacific Coast CL-85 micro chiller. 1/4 HP Oceanic Aquarium Chiller. The first one’s output is 85 watt. 80-160 Gallons per hour is the optimal flow rate. The dimensions are: 4" x 4 3/4" x 7 1/2" . The second one’s flow rate is between 475 and 800 Gallons per hour. The dimensions are: 13 x 17 x 17.31 .

Running nutrient thru the chiller compared to using a cool

Dec 28, 2020· I see most people are running their nutrient directly thru a chiller and not using stainless steel coil in epicenter to cool. Does the coil just not work? I read it takes 1ft of 3/8 stainless steel to cool 12.5 gallons of water. I was going to get 3 50'' 1/2 wort chiller to drop in epicenters to cool using a 275 gallon chiller rez and manifold

What to Do When Refrigerator Is Not Cooling but Freezer Is

Jul 20, 2021· 4. Iced-Up Evaporator Coils. The evaporator coils are where the air goes to cool down. However, if they''re covered in frost, the air can''t pass through efficiently and won''t get adequately cool, resulting in a warm fridge. A quick fix is to defrost the coils with a hairdryer, which will temporarily solve the issue.

5 Chiller Tips & Tricks For Cold Weather - American

2. Keep the chiller condenser coils clean and clear of snow and ice. Ice and snow can damage fan blades and restrict air flow through the condenser – reducing the cooling potential of the chiller. 3. Manually control your head pressures. Head pressures drop during extremely cold weather and if your chiller isn’t equipped with low aient

Emergency Chiller Service: A Troubleshooting Guide

Nov 01, 2003· If the chiller isn’t running, find the electrical diagram of its control and high voltage circuits. This will be very necessary with an older chiller not equipped with built-in diagnostics. The reason a compressor doesn’t engage is usually due to an "open" condition somewhere in the control circuit.

Alliance 2695 Sample Heater/Chiller will not cool to set

Dec 20, 2021· SYMPTOMS. Sample heater chiller does not cool to the set point. Sample compartment is defrosted, but still does not reach set point. Room temperature is normal with no fluctuations. No heat source near instrument.

What is the reason why the chiller is not cooling?

Jul 16, 2020· The pipes are also prone to scale, breed bacteria, and reduce the cooling effect. Therefore, the equipment and pipes need to be cleaned and maintained regularly. Insufficient power supply voltage and too long copper pipes connecting the indoor unit and the outdoor unit will also cause the chiller or air conditioner to not cool.

How to Troubleshoot Chiller Problems

chiller from running. 2. Determine if the chiller is cooling. Check the temperature of the coolant at the chiller’s outlet to the process. If it isn’t at or near the set point temperature, the evaporator may be iced up or the heat transfer properties of the coolant fluid may be deteriorating. 3. Confirm that the pump is running.

Running nutrient thru the chiller compared to using a cool

Dec 28, 2020· I see most people are running their nutrient directly thru a chiller and not using stainless steel coil in epicenter to cool. Does the coil just not work? I read it takes 1ft of 3/8 stainless steel to cool 12.5 gallons of water. I was going to get 3 50'' 1/2 wort chiller to drop in epicenters to cool using a 275 gallon chiller rez and manifold

Killer chiller

Feb 28, 2019· the killer chiller didn''t really add power per say but it would keep IAT2s down and prevents timing from being pulled without having to use ice between runs. I had one on my Lightning and it worked well at the expense of some in-cab cooling. This was before the j2fab style mods to increase flow in and out of the intercooler was a thing.

How to Run a Chiller Plant in Hand - HVAC Training Shop

Jan 02, 2019· This air-cooled chiller has its own internally-controlled chilled water pump that should not be started manually. Step 4: Start Cooling Tower (s) This step is only required if the chiller (s) are water-cooled. Start the cooling tower fan (s) and ensure that they are running at a proper speed (if they are speed controlled).

Whirlpool Refrigerator - Refrigerator Not Cooling - Repair

If the condenser fan motor is not working properly, the refrigerator won’t cool properly. To determine if the fan motor is defective, first check the fan blade for obstructions. Next, try turning the fan motor blade by hand. If the blade does not spin freely, replace the condenser fan motor. If no obstructions are present and the fan blade

Stupid A/C Chiller System Question - HVAC | YachtForums

Jul 01, 2021· The general rule of thu for heat exchange in the air handlers is 20 degrees. So if your chiller water at the air handler is 52, your cabin temp is going to struggle to approach 70 degrees. The heat outside/UV will challenge that cooling effort and result in your mid 70''s.

Chiller Troubleshooting 101

Apr 24, 2014· Chiller Troubleshooting 101. Production » Refrigeration posted Apr 24th, 2014 by Stan Hieronymus. There is a good chance your glycol chiller system is often completely forgotten about, until that dreaded day you arrive to find high fermenter temperatures and your glycol chiller system is not running.

Emergency Chiller Service: A Troubleshooting Guide

Nov 01, 2003· 9. The chiller is running. Great! Now install gauges and temperature probes and begin taking readings. At this point you''re ahead of the game, but not out of the woods. You need to find out why the system either tripped a safety or isn’t running the way the customer desires. Common Chiller Troubleshooting Problems

Chiller not cooling the water | 3reef Aquarium Forums

Jul 13, 2010· You can cut the lights back also to keep them cool until the gages arrive go out tomorrow they should be there by Friday. Get a can of 134a you might want to look it over for a leak also a connection and the area will be oily looking from the …

Winter Chillers and Preventing Major Problems - Chillers

Mar 09, 2018· The contents of the chiller probably need to be kept within a specific temperature range. The exterior winter temperatures still might not create the ideal environment for whatever is being stored. Chillers still cannot fail, even when it’s generally cold outside. Using specialized chillers that can truly handle winter temperatures can truly

Cooling Tower vs. Chiller | How Cooling Towers and

Jul 10, 2019· Cooling tower temperatures vary based on local wet bulb conditions and the aient air temperature. Typical low temperature coolant temperatures during summer conditions can rarely go below 75F-80F while using a cooling tower. Chillers can achieve typical temperatures from 70F and below all year. Some chiller designs can allow for cooling

<script type="text/javascript" src="https://s4.cnzz.com/z_stat.php?id=1281050184&web_id=1281050184"></script>