Send Email To Us
Email:[email protected]
  • BHO extractor closed loop

    BHO extractor closed loop

    Sells 1 lb, 10 lb, 20 lb, 50 lb and other closed-loop extractors, which are made of stainless steel, are inexpensive and have high extraction efficiency.

  • SPD2L short path distillation

    SPD2L short path distillation

    Sells a complete set of SPD-2L mini short-path distillation equipment, which is widely used in pharmaceutical, laboratory fractionation and purification, food and beverage, essential oil and other industries.

  • RE5299 rotary evaporator

    RE5299 rotary evaporator

    Our company's rotary evaporator RE-5299 rotary evaporator uses high borosilicate glass, with sufficient storage, cheap and good quality.

  • RE201D 301 501 rotary evaporator

    RE201D 301 501 rotary evaporator

    RE-201D RE-301 RE-501 rotary evaporator is a small rotary evaporator (mini rotary evaporator), beautiful appearance, small and light, top-rotating sealed, good vacuum.

  • S80L 100L glass jacketed reactor

    S80L 100L glass jacketed reactor

    Is specializes in manufacturing and selling laboratory large-capacity glass reactors. Double-layer glass reactors can be customized and processed according to customer needs. The design is unique, safe and convenient.

  • S10L 20L 30L 50L glass jacketed reactor

    S10L 20L 30L 50L glass jacketed reactor

    Is specializes in manufacturing and selling S-10L S-20L S-30L S-50L laboratory glass reactors, which can perform various solvent synthesis reactions under constant temperature conditions.

  • FD03H freeze dryer

    FD03H freeze dryer

    Home lab freeze dryer is a mini vacuum freeze dryer. We are a freeze dryer manufacturer in China. We sell freeze dryers, which are very suitable for home use.

  • DZF6500 vacuum drying oven

    DZF6500 vacuum drying oven

    The vacuum drying oven with vacuum pump can achieve the effect of vacuum drying.Provides vacuum drying ovens of various specifications.

  • KDM100 molecular distillation

    KDM100 molecular distillation

    A professional laboratory molecular distillation system manufacturer in China. Its evaporation efficiency is very high, it can reduce the retention time and has the smallest time delay.

Categories
Related Posts

sop for centrifuge

Standard Operating Procedures - University of California

Standard Operating Procedures Laboratory Specific – Biochemistry Shared Instrumentation Facility Centrifuges – All sizes and speeds _____ Department: Chemistry and Biochemistry Date when SOP was written: Sept 20, 2012 Date when SOP …

Standard Operating Procedure

1.1 SOP: Standard Operating Procedure . 1.2 CRF: Case Report Form . 2. Purpose / Background 2.1. The purpose of this SOP is to provide guidance for the processing, testing and storage of all PERCH study 1 Centrifuge the plain blood tube at 3000 rpm for 10 min to separate blood cells 2 Transfer serum in 500 μL aliquots into Sarstedt tubes

The Basics of Centrifuge Operation and Maintenance | Lab

Jul 18, 2019· Centrifuge rotor speed is often expressed as RCF in units of gravity (x g) for various procedures. However, many centrifuges display speed as revolutions per minute (RPM), necessitating conversion to ensure the correct experimental conditions. The following formula is used to convert RPM to RCF, where R is the rotor radius (cm) and S is the

Released by/Date Effective: Author Name Title Signature

Standard Operating Procedure Use and Maintenance of the Eppendorf Centrifuge . Document ID: HSL_EQ_020 . Version 1.0 Page 7 of 10 . 8.5.3. Attach and tighten rotor lid. 8.6. Loading Swing-Bucket Rotor: Note: When using the A-2-MTPs, centrifuge without the upper shell of the wind shield in order to guarantee precise and quick temperature control

SOP.008 Operation of the Fixed Angle Centrifuge

SOP.008 Operation of the Fixed Angle Centrifuge Updated June 16, 2020 - Page 1 of 2 Purpose The purpose of this SOP is to provide instruction in the proper use of the fixed angle centrifuge. Materials 1. 70% ethanol 2. Kimwipes Methods 1. Select the appropriate rotor for the run. Wipe down the rotor and centrifuge chaer with 70% ethanol.

Standard operating procedure of refrigerator centrifuge

Standard operating procedure of refrigerator centrifuge 1. Purpose: This instruction describes how to use and maintain a refrigerated centrifuge. 2. Operating range: This device is for centrifugation in a maximum volume of 50ml. 3. Responsibility: The laboratory expert is responsible for the correct operation of

SOP.008 Operation of the Fixed Angle Centrifuge

SOP.008 Operation of the Fixed Angle Centrifuge Updated June 16, 2020 - Page 1 of 2 Purpose The purpose of this SOP is to provide instruction in the proper use of the fixed angle centrifuge. Materials 1. 70% ethanol 2. Kimwipes Methods 1. Select the appropriate rotor for the run. Wipe down the rotor and centrifuge chaer with 70% ethanol.

Standard Operating Procedure (SOP) for processing

This standard operating procedures (or SOP) describes methods for processing specimens of cerebrospinal fluid (CSF), lymph nodes and tissues for testing using the Xpert MTB/RIF assay and for purposes of culturing Mycobacterium tuberculosis culture on solid media or liquid media. Centrifuge at 3000 g for 15 minutes. Carefully pour off the

School of Earth and Environment | University of Leeds

Centrifuge maintenance is critical to keep centrifuge users safe. The centrifuges that require regular (monthly) maintenance are Sigma 2-16 (9.129), Eppendorf 5810 (9.136), Sigma 4-16KS (9.134), and Thermo IEC CL10 (8.130a). Other smaller centrifuges do not require this. All centrifuges receive annual or biannual professional maintenance.

Use of the Centrifuges for the Processing of Clinical

CRF-LAB-SOP-1 v4.0 5.1.8 Stay with the centrifuge until it gets up to its set speed. If the blood tubes are not properly balanced or there is a problem with a bucket or the rotor, the centrifuge will make an unusual noise and shake. If this happens, stop the centrifuge, open the lid and assess what caused the ialance, correct

WO-MFD-B314S-1-20180504153728

ASE T Centrifuges Faculty of Technology and Trades Rooms: WA129 and WA130 Date Created: 04-June-14 Date Modified: May 2018 1.0 Purpose Version #: 2.0 Supersedes: 1.0 Prepared by: Applied Science and Environmental Technology (ASET) representative This standard operating procedure (SOP) provides general instructions for the safe operation,

Winthrop University

The goal of this SOP is to train personnel in the safe operation of high speed centrifuges, both fixed rotor and swinging bucket rotor types. This SOP does not apply to microcentrifuge units. SCOPE. SOP applies to everyone who is working with centrifuges. MATERIALS NEEDED. Centrifuge tubes and caps. Millipore water for balancing. Two pan

Use of the Centrifuges for the Processing of Clinical

2.1 The purpose of this Standard Operating Procedure (SOP) is to describe the procedures for the safe operation and routine maintenance of the Eppendorf 5702R and Labofuge 400R model centrifuges which are loed within the Experimental Medicine Facility (EMF) and Clinical Trials Facility (CTF). 3.0 Scope

Cleaning a Biological Spill Inside the Centrifuge

2. Unplug the centrifuge and allow the rotor to completely stop; 3. Allow 20-30 minutes for any aerosols that were generated to settle before opening the centrifuge; 4. Put a visible sign to inform others about the spill in the centrifuge; 5. Be sure to choose the right disinfectant that will not damage the centrifuge and parts.

SOP on Operation and Cleaning of Centrifuge - Pharma

This SOP describes the procedure for operation and cleaning of Centrifuge. Procedure: Operation Connect the three pin plug with the main supply. To ensure that the rotor has been correctly loaded with its components of tube and buckets, the centrifuge can be started by closing its lid. Now move the speed control knob clock wise from “0” position.

ABPDU Video SOP: Disc Stack Centrifuge (DSC) -

In this video SOP, ABPDU staff describe how to set up and operate the Disc Stack Centrifuge system for use in processing material generated from microbial fe

A BIOFIZZ SKILLS CENTER STANDARD OPERATING …

STANDARD OPERATING PROCEDURE A BIOFIZZ PRODUCTON Centrifuge 1 Module Hours: 3.0 Effective Date: 01/17/2022 PRQs Lab Safety Pipetting Revision # 1.0 M. Stowell Checked: Z. Hazlett-Klein, M. Guzie - 4 - 6.3.3. For a continuous run (hold), turn the time dial clockwise to the limit stop. Two minus signs (–) will be illuminated in the time display.

Equ 1.2-01 - pSMILE

2 Set the centrifuge timer at a setting frequently used in procedures, and start the NIST stopwatch simultaneously. 3 Stop the NIST stopwatch at the same time as the centrifuge timer ends. 4 Record both times of the stopwatch and the timer setting, as accurately as possible, on the Centrifuge Calibration Verifiion Record Sheet.

SOP CRF.L109 V1.3 Use of the Refrigerated Centrifuge

After the centrifuge has started the lid key will become disabled and the red light will be unlit. 27. Once the centrifugal run is complete the investigator or delegated person must open the lid of the centrifuge by pressing lid key on the on the front panel of the centrifuge, when there is a yellow light this indies that the lid

Centrifuge Standard Operating Procedures

{Open the lid of the centrifuge and check for condensation. If the centrifuge is wet and/or dirty, clen it out including the spindle. {Check that the main large seal on the top of the centrifuge is clear of obstructions. {Using the OVERTEMP knob, set the red bar of the temperature meter well above the aient temperature. {Turn the POWER switch ON.

Standard Operating Procedure (SOP) - PLOS

9. Centrifuge at 13.000 x g for 5 minutes. 10. Pour off the supernatant. Add 700 µl of Ethanol 70% and invert the tubes to wash DNA pellets. 11. Centrifuge at 13.000 x g for 5 minutes. Carefully pour off ethanol. The pellet may be loose so pour slowly and watch the pellets. 12.

SOP - OPERATION AND CALIBRATION PROCEDURE FOR CENTRIFUGE

Jul 27, 2008· 5.1.3 Remove the centrifuge head once in a month, apply grease at threading and fix it properly. 5.2 PROCEDURE FOR OPERATION. 5.2.1 Keep the instrument on stable platform. 5.2.2 Before operating the instrument, the speed knob and timer must be in ‘OFF’ position. 5.2.3 Put the main switch and the instrument switch to ‘ON’ position.

How to Use a Centrifuge Safely - University of California

Apr 15, 2021· Fill and open centrifuge tubes, rotors, and accessories in a biological safety cabinet (BSC). Use sealed tubes and safety buckets that seal with O-rings. Before each use inspect tubes, O-rings, and buckets for cracks, chips, erosions, bits of broken glass, etc. Do not use aluminum foil to cap centrifuge tubes—it may detach or rupture during

ABPDU Video SOP: Disc Stack Centrifuge (DSC) -

In this video SOP, ABPDU staff describe how to set up and operate the Disc Stack Centrifuge system for use in processing material generated from microbial fe

A BIOFIZZ SKILLS CENTER STANDARD OPERATING …

STANDARD OPERATING PROCEDURE A BIOFIZZ PRODUCTON Centrifuge 1 Module Hours: 3.0 Effective Date: 01/17/2022 PRQs Lab Safety Pipetting Revision # 1.0 M. Stowell Checked: Z. Hazlett-Klein, M. Guzie - 4 - 6.3.3. For a continuous run (hold), turn the time dial clockwise to the limit stop. Two minus signs (–) will be illuminated in the time display.

STANDARD OPERATING PROCEDURE - Stop TB

This SOP describes the optimal operation of a centrifuge through regular servicing and preventive maintenance. Definitions and abbreviations The relative centrifugal force (RCF) is determined according to the formula RCF = 1.12 x 10–6 x R x (rpm)2 where: RCF is in g R

Centrifuges – Environmental Safety and Health - UC

Centrifuges are a very powerful tool used for many routine procedures in the biological laboratory. Centrifuges can spin at extremely high rotations per minute (rpms) and impart great energy onto samples, thus increasing the risk of aerosol generation. This equipment can also present a physical hazard due to mechanical stress or fatigue. When utilizing centrifuges […]

Cleaning a Biological Spill Inside the Centrifuge

2. Unplug the centrifuge and allow the rotor to completely stop; 3. Allow 20-30 minutes for any aerosols that were generated to settle before opening the centrifuge; 4. Put a visible sign to inform others about the spill in the centrifuge; 5. Be sure to choose the right disinfectant that will not damage the centrifuge and parts.