Send Email To Us
Email:[email protected]
  • BHO extractor closed loop

    BHO extractor closed loop

    Sells 1 lb, 10 lb, 20 lb, 50 lb and other closed-loop extractors, which are made of stainless steel, are inexpensive and have high extraction efficiency.

  • SPD2L short path distillation

    SPD2L short path distillation

    Sells a complete set of SPD-2L mini short-path distillation equipment, which is widely used in pharmaceutical, laboratory fractionation and purification, food and beverage, essential oil and other industries.

  • RE5299 rotary evaporator

    RE5299 rotary evaporator

    Our company's rotary evaporator RE-5299 rotary evaporator uses high borosilicate glass, with sufficient storage, cheap and good quality.

  • RE201D 301 501 rotary evaporator

    RE201D 301 501 rotary evaporator

    RE-201D RE-301 RE-501 rotary evaporator is a small rotary evaporator (mini rotary evaporator), beautiful appearance, small and light, top-rotating sealed, good vacuum.

  • S80L 100L glass jacketed reactor

    S80L 100L glass jacketed reactor

    Is specializes in manufacturing and selling laboratory large-capacity glass reactors. Double-layer glass reactors can be customized and processed according to customer needs. The design is unique, safe and convenient.

  • S10L 20L 30L 50L glass jacketed reactor

    S10L 20L 30L 50L glass jacketed reactor

    Is specializes in manufacturing and selling S-10L S-20L S-30L S-50L laboratory glass reactors, which can perform various solvent synthesis reactions under constant temperature conditions.

  • FD03H freeze dryer

    FD03H freeze dryer

    Home lab freeze dryer is a mini vacuum freeze dryer. We are a freeze dryer manufacturer in China. We sell freeze dryers, which are very suitable for home use.

  • DZF6500 vacuum drying oven

    DZF6500 vacuum drying oven

    The vacuum drying oven with vacuum pump can achieve the effect of vacuum drying.Provides vacuum drying ovens of various specifications.

  • KDM100 molecular distillation

    KDM100 molecular distillation

    A professional laboratory molecular distillation system manufacturer in China. Its evaporation efficiency is very high, it can reduce the retention time and has the smallest time delay.

Categories
Related Posts

procedure for centrifuge

Procedure for centrifugal fecal flotation - DVM 360

Oct 01, 2010· Procedure for centrifugal fecal flotation. Septeer 30, 2010. Joyce S. Knoll, VMD, PhD, DACVP. A quick step-by-step to performing this procedure. 1. Mix about 2 to 5 g of feces with 10 ml flotation solution, and pour the mixture through a tea strainer into a cup. For ease of cleaning, the tea strainer can be lined with a 4-x-4-in gauze square.

Standard Operating Procedure: Serum & Plasma Sample

Ver. 1.1 05/24/2013 Page 5 of 6Plasma & Serum Sample Clarifiion Via Centrifuge - UVM Procedure 5.1.2 Method 2: High volume and/or multiple aliquot procedure Step 1: Thaw sample at 37°C for 5-7 minutes, or until sample is fully thawed. Step 2: Vortex Sample to mix well. Step 3: Centrifuge sample(s) at 14,000g for 10 minutes

A Centrifuge-Based Procedure for Suspended Solids

After a 1-h operation, the 500-mL sample was transferred to a 1-L graduated cone where the sludge volume was measured after 1 day [23]. The centrifuge-based procedure (described by North Carolina

CENTRIFUGE CALIBRATION INSTRUCTIONS

there is no reflective tape on the centrifuge then loe the extra tape mailed to the facility with the digital tachometer. Cut a small strip and place it on the centrifuge in the center where it is on the rotating part of the centrifuge. Close the lid and turn on the centrifuge. Let it run for at least a minute so that it is running at full

C4. Procedure for serum and plasma separtion

1. A 10 ml tube of whole blood will be collected following standard procedures using a serum separator tube (SST, tiger top tube) from each patient. 2. Allow samples to clot for one hour at room temperature 3. Centrifuge for 10 minutes at approximately 1000g 4. Using clean pipette technique Aliquot 210ul of serum into labeled cryovials. 5.

Calibration of centrifuge machine with operation, and

[][]To ensure that the instructions of this procedure are correctly followed. [][]To ensure cleaning of centrifuge machine maintaining safety rules. Manager, Quality Control [][]To ensure that this procedure is kept up to date. [][]To confirm that the SOP is technically sound and reflects the required working practices.

Laboratory Outreach Centrifuges (LTR27054)

Laboratory Outreach Centrifuge Procedure Principle: The pre-analytic phase of laboratory testing consists of: specimen collection, processing, handling, transportation, and physiological issues which all have an important impact on the integrity of laboratory test results. In order to maintain the highest specimen integrity, a centrifuge may be

Standard Operating Procedure (SOP)

Centrifugation SOP template 7 Revised: 06/2019 MTD 6. Step-by-Step Operating Procedure Provide the steps required to perform this procedure. For a process: Write enough detailed description of the procedure to guide the user through the process including details of startup, normal condition operation, temporary operation condition, and emergency

Routine Maintenance of Centrifuges - Eppendorf

Centrifuge maintenance is an everyday tool to maintain optimal condition and safety of laboratory devices. To fol- soft cloth for waxing procedure. The rotor chaer sealing can be lubried as well, especially after disinfection with ethanol. Please use glycerol or talcum for lubriion.

Safe Operating Procedure - University of Nebraska–Lincoln

General centrifuge decontamination procedures can be found in the EHS SOP, Biological Decontamination of Laboratory Equipment • If the material involved was a radioactive material, promptly contact EHS. A contamination survey must be …

Centrifuge Safety – Stanford Environmental Health & Safety

If a specific procedure does not allow for this, contact EH&S at (650) 723-0448 for guidance. For high speed centrifuges and ultracentrifuges, use an in-line filter in the vacuum line to prevent contamination of the vacuum pump and pump oil. Provide secondary containment for vacuum pump. Centrifuge Operation. Balance centrifuge. Start run

How to Centrifuge Blood for PRP | PRP Centrifuge Procedure

Mar 08, 2022· If you need to store the blood, maintain about 20°C to 24°C. Put it in a centrifuge and spin it at a ‘high’ speed. This results in three (3) layers. Bottom RBC layer, middle platelets and WBCs and the top PPP layer. Remove the top layer, and take the middle layer and discard the bottom layer.

High-Speed Centrifuges for Lipemia Removal in Serum/Plasma

Hettich high-speed centrifuges, the low-cost alternative for lipemia removal in serum/plasma samples: Save thousands in equipment costs as compared to ultracentrifuges (upwards of ~$15k) Successfully clear lipemic samples with no reagents or additives. Obtain versatility for multiple appliions with multiple rotor options and a compact footprint.

WO-MFD-B314S-1-20180504153728

Standard Operating Procedure COLLEGE ASE T Centrifuges Faculty of Technology and Trades Rooms: WA129 and WA130 Date Created: 04-June-14 Date Modified: May 2018 1.0 Purpose Version #: 2.0 Supersedes: 1.0 Prepared by: Applied …

Use - Stanford University School of Medicine

Centrifuge Use There are a few important guidelines for operating a centrifuge, even a small one. Following them can prevent damage to the centrifuge and possible serious injury to you and others. Use 1. The work surface must be level and firm. Do not use the centrifuge on an uneven or slanted work surface. 2. Balance the tubes in the rotor! If

Standard Operating Procedures - University of California

1) Place temperature equilibrated rotor into centrifuge. Mind that teeth and groves interlock between rotor and centrifuge. 2) Place balanced tubes into opposite corresponding positions. For multiple balanced pairs, distribute them evenly around the rotor. 3) Secure rotor lid. 4) Start spin according to experimental protocol.

Specimen Preparation Procedures | Services for Health Care

Centrifuge specimens for 15 minutes in the MLHL-provided centrifuge. Package specimens as directed in the Directory of Services. Standard non-gel collection tubes. Perform a routine venipuncture. Collect approximately 10 ml of whole blood using a standard red top blood collection tube (no additives) for each 5 ml of serum required.

QCA.007 Functional Calibration of Serological Centrifuges

Apr 05, 2004· Principle. To determine the optimal time of centrifugation for agglutination tests. Scope and Related Policies. 2.1. The speed of rotation and the timing device of a centrifuge shall be calibrated on installation, following servicing and maintained as per manufacturer’s recommendation’s 9.1 or every six months when not specified.

SOP CRF.L109 V1.3 Use of the Refrigerated Centrifuge

Use of the Refrigerated Centrifuge 30/10/2013 Page 2 of 6 Standard Operating Procedure: NIHR Sheffield Clinical Research Facility Use of the Refrigerated Centrifuge This SOP has been written to give general guidance to study personnel on how to use a centrifuge. There are no Good Laboratory Practice Guidelines concerning the use of a centrifuge.

General Centrifuge Safety - University of British Coluia

your own centrifuge safety plan is not intended to be complete and may contain errors and omissions. For accurate up-to-date information please contact the manufacturer. Standard Operating Procedures must be followed when using centrifuges to ensure that all centrifuges in UBC laboratories are used, cared for and maintained in a safe manner.

Fecal Flotation Procedures - Dr. Michael Dryden

♦ Another good centrifuge is the Clay Adams Dynac III Centrifuge . • Centrifuge # B420104 $3,543.20 • Horizontal rotor & 8 – 15ml shield kit # NC9101223 $820.50 . • Centrifuge # 20903-070 $3,530.96 • Horizontal rotor & 8 – 15ml shield kit # 20902-790 $738.202 ♦ Also from www

Laboratory!CentrifugeOperationInstructions!

Laboratory!CentrifugeOperationInstructions! 1. Make!sure!centrifuge!is!plugged!in.! 2. Always!wear!gloves!when!handling!specimens.! 3. Place!covered/!capped!testtube!specimens!into!tube!holders.!!Make!sure!specimens!are! all!the!way!into!holders.! 4.

Centrifugation - Centrifuge Definition, Centrifuge Machine

Centrifugation Definition. Centrifugation is the process that uses centrifugal force for the separation of two liquids in a mixture. In this process, the denser component of the mixture migrates away from the axis and the lighter component migrates towards the axis. The process of centrifugation is carried out in a centrifuge, as shown in Fig 7.

Centrifuge and Rotor SOP - InsideEWU

Standard Operating Procedure Page 1 of 5 Origin Date: 5/8/2015 Revision 3 Revision Date: 2/2/2017 Introduction The purpose of this Standard Operating Procedure (SOP) is to provide guidance for the safe operation of centrifuges and rotors in the laboratory. Centrifuges are a commonly used piece of laboratory equipment. Centrifuges spin at high

Centrifuge calibration: optimal spin time - Equipment

Dec 12, 2019· The procedure for centrifuge calibration, Method 7.5 in the Technical Manual: We do this annually, and I have a question. There are the saline instructions, as well as high-protein, and Coos/cellwashing phases. My question: we don''t use albumin here, we have gel. So we do our blood typing in tube, and we use gel for antibody screens and panels.

Routine Maintenance of Centrifuges - Eppendorf

Centrifuge maintenance is an everyday tool to maintain optimal condition and safety of laboratory devices. To fol- soft cloth for waxing procedure. The rotor chaer sealing can be lubried as well, especially after disinfection with ethanol. Please use glycerol or talcum for lubriion.

centrifuge calibration - Equipment - PathLabTalk

May 22, 2015· Here is the procedure and form we use for the calibration of all of our centrifuges (Hettich EBA 21 and Sorvall Cellwasher 2). This works well for us, hope you find it useful. Terri. TS 002404 Calibration of Serologic Centrifuges.doc. TS 009002 Serologic Centrifuge Calibration Worksheet.doc. carolyn swickard. 1.

Calibration of Centrifuge Apparatus : Pharmaceutical

PROCEDURE. Ensure that all connection of instrument are proper; Operate the instrument as per the operating instructions; Use duly calibrated tachometer, digital thermometer and stopwatch during calibration of the equipment. Calibration of time. Set the time for five minutes using set parameters. Record the results by using a digital stopwatch.

<script type="text/javascript" src="https://s4.cnzz.com/z_stat.php?id=1281050184&web_id=1281050184"></script>