Sells 1 lb, 10 lb, 20 lb, 50 lb and other closed-loop extractors, which are made of stainless steel, are inexpensive and have high extraction efficiency.
Sells a complete set of SPD-2L mini short-path distillation equipment, which is widely used in pharmaceutical, laboratory fractionation and purification, food and beverage, essential oil and other industries.
Our company's rotary evaporator RE-5299 rotary evaporator uses high borosilicate glass, with sufficient storage, cheap and good quality.
RE-201D RE-301 RE-501 rotary evaporator is a small rotary evaporator (mini rotary evaporator), beautiful appearance, small and light, top-rotating sealed, good vacuum.
Is specializes in manufacturing and selling laboratory large-capacity glass reactors. Double-layer glass reactors can be customized and processed according to customer needs. The design is unique, safe and convenient.
Is specializes in manufacturing and selling S-10L S-20L S-30L S-50L laboratory glass reactors, which can perform various solvent synthesis reactions under constant temperature conditions.
Home lab freeze dryer is a mini vacuum freeze dryer. We are a freeze dryer manufacturer in China. We sell freeze dryers, which are very suitable for home use.
The vacuum drying oven with vacuum pump can achieve the effect of vacuum drying.Provides vacuum drying ovens of various specifications.
A professional laboratory molecular distillation system manufacturer in China. Its evaporation efficiency is very high, it can reduce the retention time and has the smallest time delay.
Basic Precautions: Periodically test the function of the "off" switch on each hot plate, heating mantle, and water bath to verify that it works and the device cools off quickly when the switch is in the "off" position. Always check equipment prior to use. Do not use if the plug or cord are worn, frayed, or damaged, if the grounding pin has been
These heating mantles are designed for use with round bottom flasks. Features include polyurethane coated aluminum exteriors and a high quality knitted mantle with glass fiber underlay for uniform distribution of heat. Maximum operating temperature is 400°C. Mantles can be used in a wide range….
Safety Precautions Heating mantles should never be plugged directly into an outlet. A heating mantle can easily generate enough heat to vaporize most organic materials and will melt a flask if used on full power.
1.The heating mantle with a fixed housing, which is particularly suitable for the tasks when the laboratory device can be placed on a table. 2.The heating mantle, also called the heating jacket, which is used when the heating element can be firmly fixed around the round bottom flask. Precautions for Using a Electric Heating Mantle. Jan 25
Apr 10, 2003 The heating mantle should fit the flask size. A heating mantle that is either too small or too big, has a poor contact with the flask, which damages the heating mantle. In addition, the temperature is very difficult to control. The lack of contact causes the heating mantle to overheat and burn out. A heating mantle that is slightly
Heating Bath SOP 2013 1 Standard Operating Procedure Heat Sources and Heating Baths 1. Procedure/Hazardous Material: Includes, but not limited to ovens, hot plates, heating mantles and tapes, oil baths, salt baths, sand baths, hot-air guns, and microwave ovens. 2. Department: Campus wide 3. Revision Date: February 2013 4. Special Notifiions:
Jun 01, 2021· Most oil baths are good for heating reactions <200 oC as they provide a more even distribution of heat and are easier to regulate. F or reactions requiring higher temperatures, heating mantles and sand or salt baths must …
1. Always use a heating mantle with a variable autotransformer to control the input voltage. Never plug them directly into a 110-V line. 2. Be careful not to exceed the input voltage recommended by the mantle manufacturer. Higher voltages will cause it to overheat, melt the fiberglass insulation and expose the bare heating element. 3.
Lab heating mantles are used to uniformly heat various lab and glassware vessels. If you are looking for an accurate and easy-to-use heating solution, a lab heating mantle is a good alternative to heating baths. A lab heating mantle …
Point the funnel away from the eyes and the naked flames, or heating mantle. 5.6.2 Observe special precautions when handling new organic substances of which the toxic hazards are unknown. 5.6.3 Protective eye goggles and gloves must be worn. 5.6.4 Always use appropriate pipette filler. Never fill pipette using the mouth.
Jul 05, 2017· The common heating devices used in labs are bunsen burners, hot air ovens, hot plates, heating mantles, muffle furnaces, hot oil baths and microwave digestion systems. The selection of a device depends on the appliion in hand. The risks posed by the common heating devices and precautions to be taken in their handling are discussed
Basic Precautions: Periodically test the function of the "off" switch on each hot plate, heating mantle, and water bath to verify that it works and the device cools off quickly when the switch is in the "off" position. Always check equipment prior to use. Do not use if the plug or cord are worn, frayed, or damaged, if the grounding pin has been
MANTLE 990481 1 / 7 Section: 1. PRODUCT AND COMPANY IDENTIFIION Product name : MANTLE Other means of identifiion : Not applicable. Environmental precautions : Do not allow contact with soil, surface or ground water. Methods and materials for containment and cleaning up : Stop leak if safe to do so. Contain spillage, and then collect
EM Electromantle™ heating mantles are used in wet chemistry to heat liquids in round bottom flasks. The plastic case is designed to remain “cool-to-the-touch” when in operation. Electrothermal heating mantles have a grounded stainless steel earth screen covering the element and are double fused for added safety.
Jan 25, 2019· The following are precautions when using a heating mantle. I hope it would provide some help for everyone. The instrument should be placed on a flat and stable ground. Plug in the power and turn on the switch. The green light indies power …
Heating control is provided either by a regulator built into the heating mantle (Fig. 5.13a) or by an external controller, which is connected to the mantle by a plug. Some mantles, ''stirrer mantles'', have a built-in magnetic stirrer just like …
May 03, 2019· Precautions – Keep the heating mantle in dry place and ensure that there is no spillage of the solvents on to the surface or the heating yarn. – In case of the spillage stop the operation of the unit by externally switching off the power to the unit and keep the unit to dry. Operate the unit again only when it is completely dry.
Most labs use at least one type of heating device, such as ovens, hot plates, heating mantles and tapes, oil baths, salt baths, sand baths, air baths, hot-tube furnaces, hot-air guns and microwave ovens. A nuer of general precautions need to be taken when working with heating devices in the laboratory.
The heating mantle should fit the flask size. The temperature will be difficult to control if the heating mantle lacks contact with the flask. The heating mantle will overheat or burn out if left unintended for too long. • Add the sand into the heating mantle. Make sure the sand occupies 2/3 of the heating mantle. Figure 1 Reflux Apparatus
Whenever possible, researchers are encouraged to substitute oil baths with a safer alternative such as a sand bath or a heating mantle for solvent reflux/distillation. Handling Oil Bath Assely. Mineral oil or silicone oil is …
General Precautions. When working with heating devices, consider the following: Heating Mantles. Heating mantles are commonly used for heating round-bottomed flasks, reaction kettles and related reaction vessels. These mantles enclose a heating element in a series of layers of fiberglass cloth. As long as the fiberglass coating is not worn
SP Wilmad-LabGlass Hemispherical Micro Heating Mantles, SP Industries. alog Nuer: (14200-156) Limited time offers. Supplier: SP Industries. Description: These micro heating mantles are made of soft, all glass fabric and support the bottom half of glass flasks. ,14200-156EA. Retrieving Each. Sale.
1. Always use a heating mantle with a variable autotransformer to control the input voltage. Never plug them directly into a 110-V line. 2. Be careful not to exceed the input voltage recommended by the mantle manufacturer. Higher voltages will cause it to overheat, melt the fiberglass insulation and expose the bare heating element. 3.
leave any heating apparatus unattended during operation. AVOID SPILLAGES: Always fill the glassware / vessel away from the heating mantle. Only introduce a pre-filled, clean, wiped-dry flask into the heating mantle. If spillage does occur, disconnect unit from the power supply and follow instructions in the Servicing and Repair section.
2.0 BASIC OPERATION : 2.1 Switch on the heating by the mains switch. 2.2 There are one control knob on the heating mantle. 2.3 Control knob is for controlling the rate of temperature rising. 2.4 Switch of the heating mantle after usage and after coming to room temperature. 2.5 Don’t place any flammable liquids or solids directly in beakers on
Space Mantle heater handling precautions Heating Capacity (W) 100 Flask (mL) For 200 Specifiion AC100V TGK Part No. 603-60-54-03 Type E-2 . from S$269.90. Shipping. Min. 7 days. See All Products. A flexible cylindrical heater. As it is a fastener, it is easy to put on and take off, and maintenance is easy. ACl00V Allowable heat resistant
Columns up to 150 mm Long (1) Columns up to 300 mm Long (1) Fisherbrand Metal-Housed Heating Mantles; Round Bottom Flasks (1) Heating Mantles (1) Round Bottom Flasks from 50 to 250 mL (1) Single-Block Reacti-Therm …
Mantle must be operated with a temperature controller and with an appropriate sie flask, filled with fluid. 5.2.2 Never operate heating mantle without fluid within the flask 5.2.3 Fluid shouldn’t be allowed to come in contact with the cavity of the heating mantle 5.2.4 Never operate the mantle at temperatures above 450 ℃ Prepared by: Krisha
Copyright © 2022 Berlio Machinery Company All rights reserved sitemap