Send Email To Us
Email:[email protected]
  • BHO extractor closed loop

    BHO extractor closed loop

    Sells 1 lb, 10 lb, 20 lb, 50 lb and other closed-loop extractors, which are made of stainless steel, are inexpensive and have high extraction efficiency.

  • SPD2L short path distillation

    SPD2L short path distillation

    Sells a complete set of SPD-2L mini short-path distillation equipment, which is widely used in pharmaceutical, laboratory fractionation and purification, food and beverage, essential oil and other industries.

  • RE5299 rotary evaporator

    RE5299 rotary evaporator

    Our company's rotary evaporator RE-5299 rotary evaporator uses high borosilicate glass, with sufficient storage, cheap and good quality.

  • RE201D 301 501 rotary evaporator

    RE201D 301 501 rotary evaporator

    RE-201D RE-301 RE-501 rotary evaporator is a small rotary evaporator (mini rotary evaporator), beautiful appearance, small and light, top-rotating sealed, good vacuum.

  • S80L 100L glass jacketed reactor

    S80L 100L glass jacketed reactor

    Is specializes in manufacturing and selling laboratory large-capacity glass reactors. Double-layer glass reactors can be customized and processed according to customer needs. The design is unique, safe and convenient.

  • S10L 20L 30L 50L glass jacketed reactor

    S10L 20L 30L 50L glass jacketed reactor

    Is specializes in manufacturing and selling S-10L S-20L S-30L S-50L laboratory glass reactors, which can perform various solvent synthesis reactions under constant temperature conditions.

  • FD03H freeze dryer

    FD03H freeze dryer

    Home lab freeze dryer is a mini vacuum freeze dryer. We are a freeze dryer manufacturer in China. We sell freeze dryers, which are very suitable for home use.

  • DZF6500 vacuum drying oven

    DZF6500 vacuum drying oven

    The vacuum drying oven with vacuum pump can achieve the effect of vacuum drying.Provides vacuum drying ovens of various specifications.

  • KDM100 molecular distillation

    KDM100 molecular distillation

    A professional laboratory molecular distillation system manufacturer in China. Its evaporation efficiency is very high, it can reduce the retention time and has the smallest time delay.

Categories
Related Posts

rotary evaporator hazard

Selecting a Suitable Vacuum Pump for Your Rotary Evaporator

Apr 04, 2019· This could create a fire safety hazard (for example, if your solvent is ethanol), or health risks (such as when using corrosive or carcinogenic solvents). 3. Solvent Loss. In a rotary evaporator process, you''re often able to recover fairly high-purity solvent that can be reused. If your solvent doesn’t have time to condense into the

SOP STANDARD OPERATING PROCEDURE - UNE

14. Ensure speed dial is to zero and turn off motor switch the rotary evaporator. 15. If finished for the day turn off water bath and power points, and leave the rotary evaporator and work area in a safe, clean and tidy state. Section 4 – Spill Procedure and Waste Disposal 1. Consult SDS of specific chemical for spill procedure. 2.

Rotary evaporator - Wikipedia

Rotary evaporators can also be equipped with further special traps and condenser arrays that are best suited to particular difficult sample types, including those with the tendency to foam or bump. Safety Possible hazards include implosions resulting from use of glassware that contains flaws, such as star-cracks.

Rotary evaporators for laboratories

The RV 8 rotary evaporator comes equipped with an easy to use semi-automatic lift with integrated safety ”lift-out function“ and is ideal for all standard evaporating appliions. Digital displays for both rotation speed and heating …

Rotary Evaporators’ Parts and Functions - Rotovap

May 28, 2019· A rotary evaporator (rotovap or rotavap) refers to a kind of equipment for solvent evaporation under reduced pressure, which is composed of a vacuum system, a heated water or oil bath, a condenser and a motor that rotates the evaporation flask. As its name suggests, what makes it special is that the evaporation flask can rotate. Parts of a Rotary Evaporator and …

How To Clean a Rotary Evaporator - USA Lab

Dec 22, 2020· To flush a rotary evaporator with acetone, fill up a small two-neck flask around halfway with acetone. Then, connect one socket of the flask to the rotary evaporator where the evaporation flask is typically loed. Either …

S050 Risk Assessment Using a rotary evaporator - manualzz

S050 Risk Assessment Using a rotary evaporator. RISK ASSESSMENT FORM Use this form to assist you to complete risk assessments for hazardous activities and processes. Any serious or ongoing hazards should be reported via RiskWare to ensure that appropriate corrective actions are tracked and completed. Faculty/School: Faculty of Science

Rotary Evaporators | Fisher Scientific

Bump Trap, 250mL, Rotary Evaporator, Modified, 24/40 Top Outer, 14/20 Lower Inner. Similar to CG-1320, but with the addition of two 4mm drain holes at the base of the inner tube to allow solvent to drain back into the evaporation flask. Traps have a 24/40 top outer joint and the listed size of lower inner joint.

How To Use Rotary Evaporator Distillation Alcohol?

Wear your personal protective equipment in accordance with the hazard egory of the medium to be . processed. Otherwise there is a risk of: - Splashing liquids. - Body parts, hair, clothing and jewellery getting caught. The glassware of rotary evaporator is designed for operation under a vacuum of up to 10 ar. The . rotary evaporator

Method and precautions during use of rotary evaporator

Sep 24, 2014· 1. Connect the hose to the condensate faucet and connect it to the vacuum pump with a vacuum hose. 2. First inject water into the heating tank. Zui uses pure water, and tap water should be placed for 1-2 days. 3. Adjust the main unit angle: just loosen the main unit and column connecting screws. The host can be tilted between 0-45 degrees. 4.

How to use a Rotary Evaporator - University of …

Apr 01, 2010· The flask with the solution is placed on the rotary evaporator. The use of a bump trap prevents the solution from accidentally splashing into the condenser (and being contaminated). It is highly advisable to start with a clean …

Use Of Rotary Evaporator - ursula-sauer.de

A rotary evaporator (or rotavap/rotovap) is a device used in chemical laboratories for the efficient and gentle removal of solvents from samples by evaporation.When referenced in the chemistry research literature, description of the use of this technique and equipment may include the phrase rotary evaporator, though use is often rather signaled by other language (e.g., the sample …

Rotary Evaporator Safety - LabX

A rotary evaporator is essential to distill, dry, recover, or extract samples in many labs. However, any time solvents are being used, especially under pressure and with heat, significant safety concerns arise. Below, find some common safety concerns when using a rotovap. For any rotary evaporator, refer to the manufacturer’s instructions for

How to use a Rotary Evaporator - University of California

Apr 01, 2010· The flask with the solution is placed on the rotary evaporator. The use of a bump trap prevents the solution from accidentally splashing into the condenser (and being contaminated). It is highly advisable to start with a clean bump bulb in case something bumps over after all! This would allow the experimenter to recover the solution or solid. 3.

IOWA STATE UNIVERSITY

The rotary evaporators operate under vacuum and should be treated as any other vacuum . glassware. The baths are electrically heated. They should neither be overly full nor allowed to run dry. policies/programs to limit the exposure to the hazard (i.e. authorizations, designated areas, time restrictions, training). Required PPE

Rotary Vacuum Evaporator at Thomas Scientific

The rotary evaporator R-100 is a high-quality, entry level Rotavapor to meet the essential needs in classical laboratory appliions. It is capable of a manually adjustable rotation speed of 20 to 280 rpm and equipped with an action jack lift for manual …

What are Appliions of a Rotary Evaporator? - …

Dec 20, 2019· A rotary evaporator is electronically controlled so that the rotation of the flask can be kept at a constant speed, and the mixture can form a film on the inner surface of the flask, creating a larger surface for heating. All …

Laboratory Rotary Evaporaors - McMaster University

TITLE: Use of Laboratory Rotary Evaporators. SCOPE: All Staff and Students within the Undergraduate Chemical Biology program. RESPONSIBILITY: Lab Coordinators and Technical Staff Care should be taken when preforming work under vacuum as it can result in an implosion with the possible hazard of flying glass, chemical spills and or fire

Rotary Evaporators | Fisher Scientific

Bump Trap, 250mL, Rotary Evaporator, Modified, 24/40 Top Outer, 14/20 Lower Inner. Similar to CG-1320, but with the addition of two 4mm drain holes at the base of the inner tube to allow solvent to drain back into the evaporation flask. Traps have a 24/40 top outer joint and the listed size of lower inner joint.

Hazard Assessment: Potential Hazards Associated with the

Rotary Evaporator (rotovap) Working with a Rotovap presents a health hazard to employees depending on what solvent is used. Ensure that work with a rotovap is done in a well ventilated area, a fume hood in preference, to control vapor emissions into the lab space and minimize potential employee exposure to solvent vapors.

Rotary Evaporators | Environmental Health & Safety | UMass

Rotovaps, used to remove solvent under reduced pressure from mixtures, can present a variety of hazards in the lab. This document reviews those hazards and provides helpful tips for mitigation. Rotary Evaporators | Environmental Health & Safety | UMass Amherst

Vacuum and High Pressure System Safety - UW–Madison

Rotary-evaporator taped to prevent implosion hazard. The vacuum system shall be been arranged to allow the equipment to be moved without transmitting strain to the neck of the flask; flasks are to be supported from below as well as by their necks; The vacuum apparatus must be well out of the way of traffic to avoid being struck accidentally

Rotary Evaporator Overview - Lab Instrument Manufacturer

Rotary evaporation involves a multitude of sample concentration or liquid extraction techniques from solvent reclamation, chromatography fractions, solvent removal procedures, trapping of hazardous waste liquids, and separation of non-volatile solutes from volatile solvents.

Rotary evaporator advantages and disadvantages uses in

1.About the degree of vacuum: The vacuum degree is the most important process parameter of the rotary evaporator, and users often encounter the problem that the vacuum degree cannot be hit, which is often related to the nature of the solvent used.The biochemical pharmaceutical industry often uses acetic acid, ethanol, propanol, ethyl ester, ethyl ether, petroleum ether, …

Rotary Evaporator Hazards - myfifa.pl

2. BUCHI Rotavapor™ R-300 Rotary Evaporator with Controller. The R-300 meets the highest expectations in convenience and versatility. Its modular design allows extension of the Rotavapor™ R-300 to a fully integrated system where a central interface regulates each component. Promotions are available.

Rotary Evaporator Definition - What Is A Rotary …

A rotary evaporator is a piece of laboratory apparatus that consists of a highs speed motor that spins the evaporation flask, a water bath, a condenser that is used to separate solvents from samples under low pressure, and a vacuum …

Home | Environmental Health & Safety | UCI

In general the main hazards and controls associated with Rotary Evaporation are: Risks and Hazards Controls Vacuum/Reduced pressure Implosion Ensure that there are no star cracks, chips, or defects in the glassware Always keep the rotovap in the fume hood with the sash down

Vacuum and High Pressure System Safety - UW–Madison

Rotary-evaporator taped to prevent implosion hazard. The vacuum system shall be been arranged to allow the equipment to be moved without transmitting strain to the neck of the flask; flasks are to be supported from below as well as by their necks; The vacuum apparatus must be well out of the way of traffic to avoid being struck accidentally

<script type="text/javascript" src="https://s4.cnzz.com/z_stat.php?id=1281050184&web_id=1281050184"></script>